Article

Treatment of Bifurcation Coronary Artery Disease with the Dedicated Cappella Sideguard® Stent

Register or Login to View PDF Permissions
Permissions× For commercial reprint enquiries please contact Springer Healthcare: ReprintsWarehouse@springernature.com.

For permissions and non-commercial reprint enquiries, please visit Copyright.com to start a request.

For author reprints, please email rob.barclay@radcliffe-group.com.
Average (ratings)
No ratings
Your rating

Abstract

Bifurcation coronary lesions represent a significant proportion of percutaneous coronary intervention (PCI) procedures and are often technically challenging with both lower procedural success rates and higher adverse event rates than those observed in non-bifurcation lesions. Conventional techniques used to treat bifurcation lesions, including provisional stenting and various two-stent approaches, have several shortcomings. Dedicated bifurcation stents such as the Cappella Sideguard® have been developed to overcome the problems associated with the current available techniques. This review focuses on the utility of the nitinol Sideguard stent in the treatment of bifurcation lesions and discusses the benefits of its trumpet-shaped design, self-expanding properties and low-profile delivery system. Treatment of bifurcation lesions using the Sideguard stent is straightforward and not subject to some of the limitations associated with conventional PCI techniques. Several trials are currently on the way to assess the safety and clinical efficacy of this very promising stent platform.

Disclosure:Farzin Fath-Ordoubadi is a paid consultant for Cappella Medical. Mamas A Mamas has no conflicts of interest to declare.

Received:

Accepted:

Support:The publication of this article was funded by Cappella Medical.

Acknowledgements:The authors acknowledge the help of Jon VanZile in the preparation of this manuscript.

Correspondence Details:Farzin Fath-Ordoubadi, Manchester Heart Centre, Manchester Royal Infirmary, Manchester, M13 9PT, UK. E: Farzin.fath-ordoubadi@cmft.nhs.uk

Copyright Statement:

The copyright in this work belongs to Radcliffe Medical Media. Only articles clearly marked with the CC BY-NC logo are published with the Creative Commons by Attribution Licence. The CC BY-NC option was not available for Radcliffe journals before 1 January 2019. Articles marked ‘Open Access’ but not marked ‘CC BY-NC’ are made freely accessible at the time of publication but are subject to standard copyright law regarding reproduction and distribution. Permission is required for reuse of this content.

Bifurcation lesions account for 15–20% of all percutaneous coronary intervention (PCI) cases performed, representing about half a million cases annually.1 But PCI treatment for bifurcation coronary disease has historically yielded less satisfactory results than conventional stenting. The procedure is often technically challenging and has been associated with both lower procedural success rates and higher adverse event rates than observed in non-bifurcation lesions.2,3 When dealing with bifurcation disease, clinicians confront a host of challenges, including the angle of the bifurcation, a wide variety of ostial shapes and sizes, differences among lesion/vessel sizes and shapes and technical challenges unique to bifurcation lesions.

Interventional cardiologists have tried to confront these challenges in a number of ways, including provisional stenting and various dual-stent approaches using conventional straight stents adapted for ad hoc techniques. The current favoured technique is provisional stenting, which involves primary treatment of the main branch (MB) with a stepwise approach for treating the side-branch (SB) vessel. Studies such as the British Bifurcation Coronary study (BBC-1) have confirmed that provisional stenting is associated with a decreased composite end-point rate of mortality, myocardial infarction (MI) and target-vessel failure (TVF) compared with the more complicated dual-stent options.4

However, the benefit observed in the BBC-1 study was mainly achieved through a reduction in peri-procedural MI (3.6% versus 11.2%) as defined by cardiac enzyme release. There were comparable rates of target vessel failure and mortality in both treatment arms. Similar results have been observed in the Coronary bifurcations: application of the crushing technique using sirolimus-eluting stents (CACTUS) trial, which compared a dual-stent ‘crushing’ technique with provisional stenting. This trial demonstrated similar target lesion revascularisation (TLR)/target vessel revascularisation (TVR) and mortality rates in both treatment arms. Unlike BBC-1, however, it showed no difference in MI rates between the two cohorts.5

Provisional stenting has gained widespread acceptance, primarily due to technical simplicity rather than improvements in clinical outcomes, but significant challenges are still associated with the technique. During implantation, there is the risk of prolapsing plaque from the MB into the SB and carina shift, resulting in deterioration of the SB lumen. Clinical management and resolution of a compromised or obstructed SB can often be time consuming and is not always possible to rectify.

Moreover, restenosis rates following provisional stenting remain significant. For example, rates of restenosis on angiographic follow-up at six months in the CACTUS trial were 14.7%; in the Nordic-1 study, they were 19.2% at eight-month follow-up.5,6 Similarly, a pooled analysis of six randomised trials comparing provisional stenting with a complex two-stent approach revealed SB restenosis rates of 13.8%.7 This same analysis showed no benefit in major adverse cardiac event (MACE) rates, death, TLR/TVR rates or stent SB restenosis between provisional stenting strategies and more complex dual-stent strategies.7

Irrespective of the bifurcation stent strategy undertaken, there are a number of limitations common to all current techniques. These limitations include maintaining access to the SB throughout the procedure; jailing of the SB ostium by the MB stent struts, resulting in difficulty in either rewiring the SB or passing a balloon or stent into the SB; and inability to fully protect and scaffold the ostium of the SB. In the two-stent arm of the BBC-1 study, for example, there was a 15% failure rate in kissing balloons either due to failure to rewire the vessel or balloon delivery.4 Similarly, in the Nordic Bifurcation Study, a final kissing balloon (FKB) following a two-stent strategy was only performed in 74% of cases, despite its importance. The recent Nordic III study found that, while FKB did not impact clinical outcome, it was associated with a significant reduction of angiographic restenosis rates in the SB in true bifurcation lesions (7.9% for FKB versus 20% for non-FKB).8

Even drug-eluting stents (DES) appear to be less effective at reducing restenosis rates in the SB. High restenosis rates have been reported in Nordic-1, CACTUS and BBC-1 despite the use of DES. The higher restenosis rates may be due in part to decreased ostial coverage, which prohibits the antiproliferative drug coating from reaching the ostial wall.9 They may also be caused by significant coating damage on the ostial struts crossing into the MB, which occurs during the FKB pre-dilation.

To address shortcomings of both provisional and two-stent strategies, a number of dedicated bifurcation stents have been developed, including the Cappella Sideguard® (Cappella Medical Ltd., Galway, Ireland). To date, the lack of head-to-head studies comparing a dedicated SB device with the provisional technique has hampered the ability of interventionalists to determine the optimal treatment strategy for bifurcation lesions. The Cappella Sideguard stent was designed to satisfy the need for a dedicated SB device.

Technology Overview

The Sideguard is not a conventional stent platform. Instead, it represents a new approach to the treatment of bifurcation disease. The Sideguard stent is a Conformité Européene-approved, self-expanding nitinol stent that flares proximally at the ostium of the SB into a trumpet shape (see Figure 1). Unlike conventional metal stents, the nitinol stent conforms to the shape of the lumen and produces positive remodelling.10 Self-expansion allows full apposition to the vessel wall and further lumenal expansion, affording more room should intimal proliferation occur, without causing significant luminal narrowing and restenosis.

The Sideguard technology is comprised of two components: the implantable coronary sidebranch stent and a low-profile delivery system (3.2Fr). The thin-strut nitinol stent has a distal section that functions to anchor the device in the SB, while the proximal flared section achieves full ostial coverage. The stent is available in three diameters: Sideguard 2.5 for vessels between 2.25mm and 2.5mm; Sideguard 2.75 for vessels between 2.5mm and 2.75mm; and Sideguard 3.25 for vessels between 2.75mm and 3.25mm. Currently, the only length available is 10mm, for lesions of 7mm or less in length, but longer versions are expected in the future.

Unlike previous self-expanding stents, which were constrained on a catheter with a deployment sheath and ultimately delivered to the vessel upon retraction of the sheath,11 the Sideguard is delivered over a single, standard, rapid-exchange catheter identical to the standard technique for stent delivery. The stent is released when the protective sheath that keeps the Sideguard in place is split upon inflation of the balloon (see Figure 2). Once released, the Sideguard expands into place. The delivery system and the guidewire can then be removed from the SB and further stents can be delivered in the SB distal to the sideguard stent if required. If the main vessel is also to be treated, a conventional stent can be deployed as per usual practice. With this approach, Sideguard allows relatively easy treatment of SB lesions that would likely be ignored under provisional stenting.

Sideguard Placement Techniques

Before placement, both the MB and SB are wired and pre-dilated with non-compliant balloons. This pre-dilation step is crucial to proper placement. Next, the Sideguard is advanced into the SB and positioned under fluoroscopy. To help with correct placement, two proximal markers have been added to the third-generation delivery system that help the operator visualise position. When correctly placed, the most proximal of these two markers should be at the ostium border line, with the second marker 2mm from the ostial marker (see Figure 3). Placement should be verified by two projections.

After the Sideguard is advanced into position, it is then released by inflating the balloon to 12 BAR, which splits the sheath, thus releasing the stent (see Figure 4). Next, the delivery system is removed. Once the correct placement is confirmed under angiogram, the wire is removed. The Sideguard has been designed so the struts should not conflict with proper placement of the MB stent. A conventional stent of choice can now be deployed in the MB (see Figure 5). Finally, the SB and MB are rewired for the final kissing inflation.

Clinical Status

There are two possible primary causes of the high restenosis rates observed in the provisional T-stent technique and the two-stent bifurcational strategy: stent underexpansion and inadequate SB stent coverage.12,13 Early data indicate that the Sideguard addresses both of these concerns. The self-expanding and positive remodelling properties of the Sideguard address the issue of stent underexpansion, and the trumpet-shaped design offers full coverage, thus protecting the ostial and SB anatomy. Doi et al. recently reported serial intravascular ultrasound (IVUS) examination (baseline and six-month follow-up) in 11 patients treated with Sideguard stents as part of the Sideguard I first-in-man study. In this series, the authors did not report any significant restenosis at six months, despite significant intimal hyperplasia due to the self-expansion of the nitinol stent. It was observed that the self-expansion properties of the nitinol stent resulted in significant increases in stent coverage at the SB carina, thereby compensating for any intimal hyperplasia observed over the six-month time period and no net change in luminal area.10

The first-generation Sideguard clinical results were released at Transcatheter Cardiovascular Therapies (TCT) 2007, when results from 20 patients treated with Sideguard were published. The technical success rate of this first-in-human trial was 80%, with a revascularisation rate of 12.5% at six months. There were no cases of stent thrombosis.14 After this trial, the second-generation Sideguard was introduced, including the anchoring system that helped ensure more accurate placement and a more flexible, lower-profile sheath. The second generation represented a leap forward in clinical outcomes: with MACE rates of 12% at 12 months, as well as SB revascularisation rates of <5% and an MB revascularisation rate of <2%. Two cases of thrombosis were observed, one peri-procedurally and a second in-hospital procedure-related event. In the Sideguard II trial, a high technical success rate was achieved in 94% (31/33) of the final cohort.14 Cappella is currently engaged in a large-scale registry (more than 250 patients) in Europe. This real-world study includes the latest-generation dual-marker system and should confirm the ease of use and hopes to confirm low TVF. This trial is under way and expected completion is mid 2011.

In summary, the Sideguard has been designed to confront the challenges unique to bifurcation disease that have hampered existing provisional and two-stent strategies. Studies have shown that restenosis rates remain significant with both provisional and two-stent techniques.15 The Sideguard represents a straightforward approach to the treatment of bifurcation lesions and minimises technical limitations associated with conventional PCI treatment methods. An ongoing registry and planned randomised study aim to further evaluate the clinical efficacy and safety of this stent platform.

References

  1. Lefèvre T, Louvard Y, Morice MC, et al., Stenting of bifurcation lesions: a rational approach, J Interv Cardiol, 2001;14(6):573–85.
    Crossref | PubMed
  2. Latib A, Colombo A, Bifurcation disease: what do we know, what should we do? JACC Cardiovasc Interv, 2008;1(3):218–26.
    Crossref | PubMed
  3. Latib A, Colombo A, Sangiorgi GM, Bifurcation stenting: current strategies and new devices, Heart, 2009;95(6):495–504.
    Crossref | PubMed
  4. Hildick-Smith D, de Belder AJ, Cooter N, et al., Randomized trial of simple versus complex drug-eluting stenting for bifurcation lesions: the British Bifurcation Coronary Study: old, new, and evolving strategies, Circulation, 2010;121(10):1235–43.
    Crossref | PubMed
  5. Colombo A, Bramucci E, Saccà S, et al., Randomized study of the crush technique versus provisional side-branchstenting in true coronary bifurcations: the CACTUS (Coronary Bifurcations: Application of the Crushing Technique Using Sirolimus-Eluting Stents) Study, Circulation, 2009;119(1):71–8.
    Crossref | PubMed
  6. Steigen TK, Maeng M, Wiseth R, et al., Nordic PCI Study Group. Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study, Circulation, 2006;114(18):1955–61.
    Crossref | PubMed
  7. Hakeem A, Khan FM, Bhatti S, et al., Provisional vs. complex stenting strategy for coronary bifurcation lesions: meta-analysis of randomized trials, J Invasive Cardiol, 2009;21(11):589–95.
    PubMed
  8. Nordic-Baltic PCI Study Group, Randomized comparison of final kissing balloon dilatation versus no final kissing balloon dilatation in patients with coronary bifurcation lesions treated with main vessel stenting: the Nordic-Baltic Bifurcation Study III, Circulation, 2011;123(1):79–86.
    Crossref | PubMed
  9. Hahn JY, Song YB, Lee SY, et al., Serial intravascular ultrasound analysis of the main and side branches in bifurcation lesions treated with the T-stenting technique, J Am Coll Cardiol, 2009;54(2):110–7.
    Crossref | PubMed
  10. Doi H, Maehara A, Mintz GS, et al., Serial intravascular ultrasound analysis of bifurcation lesions treated using the novel self-expanding sideguard side branch stent, Am J Cardiol, 2009;104(9):1216–21.
    Crossref | PubMed
  11. Hirayama A, Kodama K, Adachi T, et al., Angiographic and clinical outcome of a new self-expanding intracoronary stent (RADIUS): results from multicenter experience in Japan, Catheter Cardiovasc Interv, 2000;49(4):401–7.
    Crossref | PubMed
  12. Iakovou I, Ge L, Colombo A, Contemporary stent treatment of coronarybifurcations, J Am Coll Cardiol, 2005;46:1446–55.
    Crossref | PubMed
  13. Costa RA, Mintz GS, Carlier SG, et al., Bifurcation coronarylesions treated with the “crush” technique: an intravascular ultrasoundanalysis, J Am CollCardiol, 2005;46:599–605.
    Crossref | PubMed
  14. Latib A, Chieffo A, The Cappella Sideguard Stent, EuroIntervention, 2010(S);6;J1–10.
  15. Ferenc M, Gick M, Kienzle RP, et al., Randomized trial on routine vs. provisional T-stenting in the treatment of de novo coronary bifurcation lesions, Eur Heart J, 2008;29:2859–67.
    Crossref | PubMed